Lenze ESV / SMVector IP31 & IP65 Fault Codes – Error Messages & Troubleshooting

Image

Introduction

The Lenze ESV and SMVector frequency inverter ranges are used in a wide variety of industrial applications, providing variable speed control for AC motors.
The SMVector range was available in two main enclosure versions: IP31 and IP65. Both versions provide inverter control for industrial applications, but their enclosure protection makes them suitable for different installation environments.
Like any inverter drive, the Lenze ESV/SMVector can display fault codes and error messages if a problem occurs with the drive, motor, electrical supply or connected control equipment.
This guide covers the Lenze ESV and SMVector fault codes, their possible causes and recommended troubleshooting checks. It also explains how to identify the drive, check previous faults and investigate potential replacement options.

Identifying your Lenze ESV / SMVector inverter

Before investigating a fault, it is important to identify the exact inverter model.
The Lenze ESV/SMVector range includes two main enclosure types:
  • IP31: Generally intended for installation inside a suitable electrical enclosure or protected indoor environment.
  • IP65: Provides a higher level of protection against dust and water ingress, subject to the manufacturer's installation requirements.
The enclosure type can be identified from the inverter's model number and product nameplate.
When contacting MDC for assistance, it is useful to have the following information available:
  • Full inverter model number.
  • Power rating and supply voltage.
  • Fault code displayed.
  • Motor rating and application details.
  • Whether the fault occurs during starting, running or stopping.
Image
Image

Lenze ESV / SMVector fault codes and troubleshooting

When the inverter detects a fault, it displays an error message and trips the drive. The fault code provides an indication of the condition detected by the inverter.
The following table covers the fault messages documented in the Lenze SMVector operating instructions.
Fault code Description Possible cause and troubleshooting
F.AF High temperature fault The drive is too hot internally. Reduce the drive load and improve cooling or ventilation
F.AL Assertion level fault The assertion level switch or parameter P120 has been changed during operation, or the input configuration does not match the selected assertion level
F.bF Personality fault Internal drive hardware fault. Cycle the power and check that the EPM contains valid data. If the fault remains, technical support may be required
F.CF Control fault An EPM has been installed that is blank or corrupted. Check or replace the EPM and restore the required drive configuration
F.cF Incompatible EPM fault The EPM contains data from an incompatible parameter version. Check the EPM and use compatible configuration data
F.cFt Forced translation fault An EPM from an older drive has been installed in a newer drive and requires data translation. Follow the manufacturer's reset procedure
F.dbF Dynamic braking fault Dynamic braking resistors are overheating. Increase the active deceleration time and check the mains voltage and braking configuration
F.EF External fault An external fault input has been activated. Check the external fault circuit and the relevant digital input configuration
F.F1 EPM fault The Electronic Programming Module is missing or defective. Isolate the supply and inspect or replace the EPM
F.F2 – F.F12 Internal faults Internal inverter faults. Consult the manufacturer's troubleshooting instructions and contact technical support if the problem persists
F.Fnr Control configuration fault Remote keypad or network control has been selected without the required communication configuration. Check the relevant control and communication parameters
F.FoL TB25 threshold fault The 4–20 mA signal at terminal TB25 has dropped below the value set in parameter P164. Check the signal and wiring
F.GF OEM defaults data fault The drive has been powered up using OEM default settings, but the stored OEM data in the EPM is invalid
F.HF High DC bus voltage fault Mains voltage is too high, or deceleration is too short and the motor is regenerating energy into the drive. Check the supply and deceleration settings
F.IL Digital input configuration fault Digital input assignments conflict or have been configured incorrectly. Check the settings of parameters P121 to P124
F.JF Remote keypad fault The remote keypad has become disconnected. Check the keypad and its connections
F.LF Low DC bus voltage fault Incoming mains voltage is too low. Check the supply voltage and connections
F.nId No motor ID fault An attempt has been made to start the drive in Vector or Enhanced V/Hz mode before completing the required motor auto-calibration
F.ntF Module communication fault Communication has failed between the inverter and its network module. Check the module connections
F.nF1 – F.nF9 Network faults Network communication faults. The exact cause depends on the communication module fitted. Consult the relevant module documentation
F.OF Output fault – transistor fault Possible output short circuit, motor cable fault, excessive motor load, acceleration time too short, excessive boost settings or failed output transistor
F.OF1 Output fault – ground fault A grounded motor phase or excessive capacitive charging current in the motor cable. Check the motor and motor cable
F.PF Motor overload fault The motor has been subjected to excessive load for too long. Check the machine, motor loading and motor protection settings
F.rF Flying restart fault The controller has been unable to synchronise with the motor during a restart attempt. Check the motor and driven load
F.SF Single-phase fault A mains supply phase has been lost. Check the incoming supply and connections
F.UF Start fault A start command was present when power was applied under the relevant starting configuration. Check the start signal and starting method
F.FAU TB5 threshold fault The 0–10 V signal at terminal TB5 has dropped below the value set in parameter P158. Check the analogue signal and wiring
Important: The fault code identifies the condition detected by the inverter. It does not automatically mean that the inverter itself has failed. The motor, cabling, electrical supply, braking components and control signals should also be considered during troubleshooting.

Understanding other Lenze SMVector messages

Not every message displayed by the inverter indicates a fault. The SMVector can also display status and warning messages to indicate its operating condition.
Examples include:
Display message Description
CAn Auto-tuning or calibration status
CL Current limit active
dEC Deceleration in progress
dr Drive is running
FCL Fast current limit active
I2t Motor overload protection warning
JOG Jog operation active
Pid PID mode active
SLP Sleep mode active
SP Start pending
SPd PID mode disabled
StoP Drive stopped
These messages indicate operating conditions or configuration states and should not be confused with the fault codes listed above.
The precise display depends on the operating mode and drive configuration.

Checking the fault history

The Lenze SMVector includes a diagnostic parameter for viewing previous faults.
Parameter P500 – Fault History records the last eight faults detected by the inverter.
The display uses the following format:
  • 1 represents the most recent fault.
  • 2 represents the previous fault.
  • The sequence continues up to 8.
  • The fault message is displayed without the initial F prefix.
For example, a fault recorded as F.AF may appear as AF in the fault history.
Checking the fault history can be particularly useful when a drive has reset or restarted but the original cause of the problem is not immediately obvious.
Recording the fault history before resetting the inverter can help identify recurring problems.

Troubleshooting common Lenze SMVector faults

Although the displayed fault code provides an indication of the problem, further investigation may be required to establish the actual cause.

Overtemperature faults

If the inverter reports a high temperature fault:

  • Check that the cooling arrangements are working correctly.

  • Inspect the drive for excessive dust or contamination.

  • Check the surrounding operating temperature.

  • Confirm that the inverter is correctly rated for the application.

Image
Image

Motor overload faults

If the inverter trips due to motor overload:

  • Check whether the machine is experiencing mechanical resistance.

  • Inspect the motor and driven equipment.

  • Check that the inverter and motor are correctly rated.

  • Confirm the motor protection settings are appropriate.

Output and ground faults

Output faults can be caused by problems with the motor, cable or inverter output stage.

Initial checks include:

  • Inspecting the motor cable and connections.

  • Checking for damaged cable insulation.

  • Investigating possible short circuits or earth faults.

  • Checking the motor for electrical problems.

  • Considering whether the acceleration time or motor cable length is suitable.

Image
Image

DC bus voltage faults

High or low DC bus voltage faults can be associated with the incoming electrical supply or the operation of the connected motor.

Check:

  • Incoming mains voltage.

  • Supply connections and phase availability.

  • Deceleration settings.

  • Whether excessive regeneration is occurring during deceleration.

  • Dynamic braking arrangements where fitted.

External and control faults

If the drive reports an external fault or control configuration problem:

  • Check the external fault circuit.

  • Inspect digital input wiring and configuration.

  • Check analogue speed reference signals.

  • Inspect remote keypad connections where fitted.

  • Check network communication connections and settings where applicable.

Image

Resetting a Lenze ESV / SMVector fault

When the SMVector trips, the fault must be reset before the drive can operate again.
The appropriate reset method depends on the fault and the control configuration.
Before attempting a reset:
  1. Record the displayed fault code.
  2. Check the fault history using parameter P500.
  3. Investigate the cause of the trip.
  4. Check that the machine and connected equipment are safe to restart.
The drive can be reset using the appropriate stop/reset controls or configured control inputs, depending on the installation.
Some faults may require the supply to be isolated and the cause investigated before the inverter can be returned to service.
Important safety information: Always isolate the electrical supply before working on the inverter, motor or associated wiring. The DC bus capacitors can retain dangerous electrical energy after the supply has been disconnected. The Lenze operating instructions specify a minimum waiting period of three minutes for the capacitors to discharge before working on the drive.
Do not repeatedly reset a drive without investigating why it has tripped.

Replacing an obsolete Lenze ESV / SMVector inverter

The Lenze ESV/SMVector range has been installed in many industrial applications, and some machines may still be operating with their original drives.
If an inverter is experiencing recurring faults, internal hardware problems or difficulties obtaining replacement components, it may be worth considering a replacement.
When selecting a replacement inverter, several factors need to be considered:
  • Original inverter model and power rating.
  • Motor voltage and full-load current.
  • Incoming supply voltage and number of phases.
  • Required speed control and operating functions.
  • Existing control wiring and machine configuration.
  • Available installation space and mounting arrangements.
  • Enclosure protection requirements.
The IP31 and IP65 versions should not automatically be treated as interchangeable. The replacement must be suitable for the installation environment as well as the electrical and control requirements.
The Lenze i500 range, including the i550 and i550 protec, may provide suitable replacement options depending on the original drive and application.
You can read more about our Lenze inverter drives and Lenze drive replacement options.

Lenze ESV / SMVector inverter support from Modern Drives & Controls

Modern Drives & Controls supplies industrial inverter drives and provides technical support for customers maintaining existing Lenze equipment.
If you are experiencing problems with a Lenze ESV or SMVector inverter, we can help identify the drive, investigate replacement options and select a suitable alternative for your application.
Whether you need assistance with an existing installation or are looking to replace an older inverter, our technical team can help.
Need help with a Lenze ESV / SMVector inverter?
Contact Modern Drives & Controls to discuss your requirements.
Contact our technical team.